Country rules in Europe: gas inspections and motorhome installations (PL, DE, NL, FR, UK, IT, SE, NO, DK, FI)
⚠️ Safety: gas and 230 V work should be carried out by a qualified installer/electrician. These guides describe principles and do not replace the standards (EN 1949, EN 1648-1/-2, IEC/HD 60364-7-721), manufacturer instructions or inspections.
Across Europe, gas installations are built to the same standard, EN 1949, and 230 V installations to IEC/HD 60364-7-721. What differs is national law: whether an inspection is mandatory, how often, and who may carry it out. The overview below is based on legislation, authorities and caravanning organisations. Rules change, so check the current position at the source (list at the bottom) before you travel.
Summary table – gas
| Country | Mandatory periodic inspection for private vehicles? | Interval | Who | Source |
|---|---|---|---|---|
| 🇩🇪 Germany | yes (German-registered vehicles) | before first use, after changes, every 24 months | G 607 expert | §60 StVZO, DVFG |
| 🇵🇱 Poland | no | – (voluntary G 607 inspection) | – | inspektomat |
| 🇳🇱 Netherlands | no | NKC advises every 2 years | – | NKC, BOVAG |
| 🇫🇷 France | no (periodic) | certificate of conformity at construction and modification | installer | Arrêté 7.06.2002 |
| 🇬🇧 United Kingdom | no (private) | annual habitation check recommended | Gas Safe required for hire/business work | GSIUR 1998, AWS |
| 🇮🇹 Italy | no, for exchange cylinders | fixed tank: entered in the registration document, valid until the 10th year | – | MIT 19042/2018 |
| 🇸🇪 Sweden | no | leak check at each cylinder change or at least every 2 years | – | MCF, Bilprovningen |
| 🇳🇴 Norway | systematic condition checks (owner's duty) | per manufacturer; DSB recommends yearly | competent person (NCB workshops) | DSB, NCB |
| 🇩🇰 Denmark | private: no; rental: every ≤ 12 months | Sikkerhedsstyrelsen recommends every 2 years | authorised firm | Sikkerhedsstyrelsen, executive order |
| 🇫🇮 Finland | no (gas not part of the roadworthiness test) | SPEK/SF-Caravan recommend yearly | pressure test only by Tukes-approved firms | Tukes, Yle/Traficom |
🇩🇪 Germany – G 607
- §60 StVZO: vehicle gas systems (up to 1.5 kg/h) must be tested to DVGW/DVFG worksheet G 607 before first use, after modifications and every 24 months.
- DVFG: mandatory since 19.06.2025. The test is not part of the general roadworthiness test (HU). Missing a valid test can be fined €15 / €25 / €60. Portable barbecues are not covered.
- Result: entry in the yellow test book and a sticker (polskicaravaning).
- Foreign vehicles: according to BOVAG, the German requirement legally applies only to vehicles registered in Germany. Campsites may still ask for proof of a test.
- G 607 high-pressure hose length: max 45 cm, 75 cm with a pull-out tray (lpgwebshop).
- Truma's manuals refer German owners to the G 607 test every 2 years.
🇵🇱 Poland
- Gas: no mandatory periodic inspection of motorhome/caravan gas systems (inspektomat).
- Electrics: PN-HD 60364-7-721:2019-05.
- Discrepancy: a polskicaravaning article gives a 10 mbar permissible drop in the leak test, EN 1949:2021 gives 5 mbar.
🇳🇱 Netherlands
- No mandatory inspection. The NKC advises a check every 2 years.
- NEN-EN 1949 is referenced in NPR 2577.
- Hoses: 5–10 years service life per manufacturer; replace clamped hoses every 2 years (NKC).
- BOVAG: the German G 607 legally applies only to German vehicles.
🇫🇷 France
- Arrêté of 7 June 2002: a certificate of conformity for the gas installation at construction and after modification (to NF EN 1949). No periodic inspection (Légifrance, jsemcamping).
🇬🇧 United Kingdom
- Gas Safety (Installation and Use) Regulations 1998, reg. 2(5): Gas Safe registration is required for work done for gain and on hire vehicles. It is not required on a private vehicle, but whoever does the work must be competent (NCC competence matrix).
- Habitation check: annual, recommended, not a legal requirement (Approved Workshops).
- Caravan Club: replace LPG hoses every 3 years and leak-test with soapy water; CO alarm to BS EN 50291-2.
- In touring caravans the high-pressure hose may be at most 0.5 m (BS EN 1949, Liquid Gas UK).
🇮🇹 Italy
- MIT circular 19042 of 3.08.2018 covers fixed LPG tanks (R67) in motorhomes and heating (R122). The tank is entered in the registration document (carta di circolazione) via the UMC.
- A fixed tank expires in its 10th year (federispettori).
- There is no mandatory periodic check for systems with exchange cylinders (Solandata, CamperLife).
🇸🇪 Sweden
- MCF: cylinders upright in a separate locker ventilated to the outside; leak check at each cylinder change or at least every 2 years; a powder extinguisher of ≥ 2 kg. Switch off gas appliances (including the fridge) before refuelling and on ferries, and close the main valve on ferries.
- Bilprovningen: the gas check is voluntary and not part of the periodic inspection.
🇳🇴 Norway
- DSB: NS-EN 1949:2021 is the recognised standard for installations in camping vehicles. Installation, repair and checks must be done by competent people. The owner must ensure systematic condition checks at the frequency the manufacturer recommends.
- CO and propane alarms are not explicitly required in vehicles, but DSB recommends them.
- Norges Caravanbransjeforbund: DSB recommends a yearly check, repairs are left to NCB workshops, and cylinders must be replaceable without tools.
🇩🇰 Denmark
- Executive order on gas installation safety §66–69: installations to EN 1949, carried out by the manufacturer or an authorised firm. The dealer inspects before handover, and the seller of a used vehicle passes on an up-to-date installation report.
- Sikkerhedsstyrelsen (class 10): commissioning leak test of 2 × 5 minutes at 150 mbar. Rental/leasing vehicles: periodic inspection every ≤ 12 months.
- Private vehicles: not mandatory; Sikkerhedsstyrelsen recommends an inspection every 2 years (DCU: no legal requirement).
🇫🇮 Finland
- Tukes: only a Tukes-approved firm (P-class competence) may pressure-test a motorhome gas system. Fixed installations and their repairs are for approved firms only.
- Traficom: the gas system is not checked in the periodic roadworthiness test (Yle).
- SPEK and SF-Caravan recommend a yearly check by an expert. A CO alarm is recommended, not mandatory.
230 V – national standards
| Country | Standard (implementing IEC 60364-7-721) |
|---|---|
| Poland | PN-HD 60364-7-721:2019-05 |
| Germany | DIN VDE 0100-721:2019-10 |
| United Kingdom | BS 7671, section 721 (IET) |
Requirements: 230 V system.
What to take on a European trip
- the latest gas inspection record (mandatory for German vehicles; campsites may ask),
- cylinder and LPG filling adapters,
- a crash-sensor regulator if you heat while driving,
- an extinguisher and a CO alarm.
🛒 Products in the carbonzorro.com shop
- Euro-Set D Professional
- LPG TANK BLANKING PLUG 11 KG – W 21,8×1/14” – LEFT HAND THREAD
- 3GAS Alarm czujnik czadu CO, LPG i narkogazów 12 V / 24 V - do kampera i przyczepy (Polish product page)
- TrioGas trivalent gas leak detector grey panel mount
- CBE BMTCO - detektor tlenku węgla, 12 V, 15 mA, szary łupkowy (Polish product page)
- CBE BMTG - LPG and soporific gas detector, 12 V, grey
- Carbest GasCube detektor gazu LPG i gazów usypiających - montaż stały, 12 do 30 V (Polish product page)
- Detektor gazu GAS-pro III CO-tlenek węgla (Polish product page)
Sources
Every figure on this page comes from the sources below (standards, manufacturer manuals, regulations). Before installing, check the current edition of the standard and the manual of your specific device.
- § 60 StVZO (DE)
- DVFG – G 607-Prüfung für Freizeitfahrzeuge
- BOVAG – G607
- NKC – Gasgebruik in de camper
- Légifrance – Arrêté du 7 juin 2002
- jsemcamping – réglementation gaz camping-car
- NCC Academy – gas competence matrix
- Approved Workshops – habitation checks
- The Caravan Club – LPG advice
- Polski Caravaning – Gaz na ulicach (PL)
- Polski Caravaning – G607 – przegląd instalacji gazowej (PL)
- Inspektomat – przegląd instalacji gazowej w przyczepie (PL)
- MCF (SE) – Gasol i husvagn och husbil
- Bilprovningen – tips för husvagn och husbil
- ACI – Circolare MIT 19042/2018 (serbatoi GPL autocaravan)
- Federispettori – scadenza serbatoio GPL
- CamperLife – Non scherziamo con il gas
- DSB – Olje- og gassinstallasjoner i kjøretøy (NO)
- Norges Caravanbransjeforbund – kontroll av gassanlegget (NO)
- Sikkerhedsstyrelsen – klasse 10, gasinstallationer i campingvogne (DK)
- Bekendtgørelse om sikkerhed for gasinstallationer (DK)
- DCU – 5 vigtige spørgsmål og svar om gas (DK)
- Tukes – koeponnistus, kirje SF-Caravanille 2018 (FI)
- Yle – matkailuauton kaasulaitteet ja katsastus (FI)
- Tukes – kaasulaitteet (FI)
- PN-HD 60364-7-721:2019-05 (PKN) oraz DIN VDE 0100-721:2019-10
- IET – Electrical installations in caravans and motor caravans
- Truma Combi (E) – operating instructions
- lpgwebshop – LPG installation in a recreational vehicle
- Liquid Gas UK – hoses and tubing information sheet
If you spot an inaccuracy, please report it to info@carbonzorro.com.
The content of this Knowledge base is for general information and illustration only. It is not technical or legal advice and does not replace standards, regulations, manufacturers’ instructions or the work of a qualified installer. Carbon Zorro Sp. z o.o. makes every effort to keep the information accurate and up to date, but does not guarantee that it is complete and accepts no liability for any consequences of its use.
Knowledge base
Questions & comments