Knowledge base

Hot water in a motorhome: boiler, Combi, FrostControl and winterising

⚠️ Note: the water system connects to a gas boiler and to 12/230 V. Leave work on the gas boiler and on 230 V to a specialist. Use only parts approved for drinking water.

Hot water in motorhomes and caravans usually comes from a boiler (gas, electric or gas/electric) or a Combi unit (blown-air heating plus boiler, e.g. Truma Combi). Vehicles with wet central heating (e.g. Alde) take hot water from the boiler’s heat exchanger. All of these share one weakness: water freezes inside and splits the vessel, so manufacturers require a safety/drain valve and careful draining before frost.

Heater, FrostControl and drain points
Fig. 1. Heater, FrostControl and drain points – click to enlarge

Types of water heaters – comparison

Appliance Capacity Energy Data from manufacturer documentation
Truma Combi 4 (gas) 10 l 30 mbar gas + 12 V (fan, electronics) gas 160–335 g/h; 12 V average 1.2 A, max. 6.5 A; quiescent current 1 mA
Truma Combi 6 10 l gas + 12 V (E versions also 230 V) gas up to 460 g/h
Truma Boiler (gas/electric) 10 l gas, optionally 230 V gas 120 g/h; 230 V element 850 W or 1300 W (by version)
230 V electric water heater e.g. 5–14 l 230 V power per rating plate – e.g. Truma TT2 5 l 300 W, 14 l boiler 850 W (shop listings)
Alde (wet heating) heat exchanger in boiler gas / 230 V fluid: 50 % glycol; safety valve 3.5 bar; water pressure reducer max. 3 bar

Combi 4 – installation requirements from the manual: wall flue ≥ 300 mm from an opening window; water connections for 10 mm hose or 12 mm John Guest; with FrostControl, max. pump pressure 2.8 bar and max. system pressure 4.5 bar.

Safety and drain valve (FrostControl)

Truma FrostControl is a current-free safety and drain valve fitted on the cold inlet of the boiler/Combi:

On the hot line after the heater, fit an air-inlet valve at the highest point – without air coming in the boiler will not empty completely.

Boiler plumbing – connection sequence

  1. Cold water from the pump → check valve (so hot water cannot flow back into the cold line) → FrostControl → boiler cold inlet.
  2. Hot outlet → air-inlet valve at the highest point → taps.
  3. Route the FrostControl drain pipe outside the vehicle, with a continuous fall, no traps, and an outlet that cannot freeze shut.
  4. Gas, flue and 230 V – per the manufacturer’s installation manual; the work should be carried out by a qualified installer (see Gas).

Winterising the water system – sequence

Winterising the water system – sequence
Fig. 2. Winterising the water system – sequence – click to enlarge

For its boilers and Combi units Truma states: switch the pump off, open the taps, open the drain valve and leave the valves open; do not blow the boiler out with compressed air and do not use antifreeze without a boiler bypass. German magazine promobil gives the same rules for the whole motorhome system.

In detail:

  1. Switch off the pump and the boiler/Combi (gas and 230 V).
  2. Open all taps in the middle position (hot + cold) and the shower.
  3. Open the FrostControl / boiler drain valve.
  4. Open the line drains and the fresh-tank drain.
  5. Disconnect the pump suction hose or open the strainer to get rid of residual water; drain the accumulator (Fiamma A20 – drain in winter).
  6. Empty the grey tank and the toilet cassette; leave the grey dump valve open.
  7. Leave everything open until spring.

Winter touring (with heating)

Hot-water service calendar

When Task Source / note
before every frost without heating drain completely (list above) Truma, promobil
once a year check the accumulator pre-charge Fiamma A20
once a year disinfect tank and lines, replace filter cartridges per product maker
every season check the flue and the FrostControl drain outlet appliance manual
every 2 years (mandatory in DE) inspection of the gas system including the boiler G 607 – see country rules

Troubleshooting

Symptom Cause What to do
FrostControl opens and dumps water valve temperature below about 3 °C heat the interior above about 7 °C and close; consider the FrostControl heating element
FrostControl will not close too cold (below about 7 °C) raise the interior temperature
Boiler does not empty completely no air inlet open the taps / air-inlet valve
Hot water flows into the cold line missing or faulty check valve fit/replace the check valve
No hot water on gas no gas, closed valve, crash sensor tripped see gas troubleshooting
Safety valve drips while running pressure too high (mains water without reducer) fit a pressure reducer

Sources

Every figure on this page comes from the sources below (standards, manufacturer manuals, regulations). Before installing, check the current edition of the standard and the manual of your specific device.

  1. Truma Combi 4 – technical data
  2. Truma – dealer catalogue 2025
  3. Truma Combi 4 – installation instructions
  4. Truma FrostControl – installation & operating instructions
  5. Alde 3020 – installation instructions
  6. Truma – draining the boiler (FAQ)
  7. promobil – Wasseranlage entleeren / Grauwassertank
  8. Fiamma A20 – accumulator manual
  9. DVFG – G 607-Prüfung für Freizeitfahrzeuge

Questions & comments

If you spot an inaccuracy, please report it to info@carbonzorro.com.

The content of this Knowledge base is for general information and illustration only. It is not technical or legal advice and does not replace standards, regulations, manufacturers’ instructions or the work of a qualified installer. Carbon Zorro Sp. z o.o. makes every effort to keep the information accurate and up to date, but does not guarantee that it is complete and accepts no liability for any consequences of its use.

Knowledge base Carbon Zorro – Carbon Zorro Sp. z o.o., ul. Humańska 8, 02-789 Warszawa · carbonzorro.com
Content compiled from manufacturer catalogues; sources are given in each brand section. Specifications are subject to change.