Charging the leisure battery: alternator, DC-DC booster, solar, 230 V charger, 13-pin socket

⚠️ Safety: 230 V wiring must be installed and tested by a qualified electrician (IEC/HD 60364-7-721). At 12 V the main hazard is fire from a short circuit – fuse every (+) cable at its source. Disconnect the batteries before working.

The leisure battery is charged from three sources: the alternator while driving (relay/separator or a DC-DC booster), solar panels via an MPPT controller, and 230 V mains via a charger or an inverter-charger. Every source must use a charge profile that matches the battery chemistry (voltages: 12 V batteries).

Charging sources compared

Source When it works Pros Limits
Relay / separator (e.g. Cyrix, D+ relay) engine running simple, cheap no charge profile; with "smart" alternators (Euro 6) the voltage may be too low
DC-DC booster (e.g. Victron Orion XS, Votronic VCC, Büttner MT) engine running full charge profile (LiFePO4 too), works with Euro 6 needs heavier cables and fuses
MPPT controller + panels daylight free energy when parked depends on weather and season
230 V charger on hook-up full charge, float only with mains power
13-pin socket (caravan) tow car engine running charging on the move usually just a trickle charge (Humbaur)

DC-DC booster (alternator charging)

DC-DC (B2B) charger from the alternator
Fig. 1. DC-DC (B2B) charger from the alternator – click to enlarge

From the Victron Orion XS 12/12-50A manual:

Parameter Value (Victron)
Fuse on input and output 60–70 A
Cable size, length < 5 m 16 mm²
Cable size, length 5–10 m 25 mm²
Clearance around the unit 10 cm; not above the battery
Terminal torques 5.6 / 4.5 / 2.8 Nm (per terminal type in the manual)
"Engine running" signal L input > 8 V or voltage detection (Euro 6 too)

Votronic VCC 1212-30: D+ input 8–17 V, draw < 1 mA, signal wire fused at 1 A; Votronic requires the D+ signal in Euro 6 vehicles.

Installation sequence (principle):

  1. Pick a ventilated spot close to the leisure battery.
  2. Run the input cable (from the starter battery) and the output cable, fused at both batteries.
  3. Connect the negative with a heavy cable to a common earth point (per the manual).
  4. Connect the ignition/D+ signal (fused per the manual).
  5. Set the charge profile (e.g. LiFePO4) and maximum current.
  6. Check operation with the engine running.

Solar panels and MPPT controller

Solar PV with an MPPT controller
Fig. 2. Solar PV with an MPPT controller – click to enlarge

From the Victron SmartSolar MPPT 100/30 and 100/50 manual:

Rule / parameter Value (Victron)
Connection order battery first, wait 10 s, then the panels
Battery fuse 100/30 35–40 A
Battery fuse 100/50 55–70 A
PV open-circuit voltage Voc ≤ 100 V (also at low temperature)
PV voltage to start charging ≥ battery voltage + 5 V
Terminal torque 1.6 Nm
PV array earthing the PV array must not be earthed
Cable strands ≤ 0.4 mm (flexible cable)

Roof mounting: bonded brackets (spoilers, corner mounts), a sealed roof cable entry, and solar cable with MC4 plugs crimped with the proper tool. Follow the bracket/adhesive maker's instructions for adhesive and surface preparation.

Series or parallel: in series the voltage adds up (watch the controller's Voc limit), in parallel the current adds up (heavier cables). With partial shading, parallel panels usually lose less. Decide using the panel and controller datasheets.

230 V charger

🛒 Products in the carbonzorro.com shop

13-pin socket (ISO 11446) – caravans

13-pin socket (ISO 11446) – caravan supply
Fig. 3. 13-pin socket (ISO 11446) – caravan supply – click to enlarge
Pin Function Cable size (Humbaur)
1 left indicator –
2 rear fog light –
3 earth for circuits 1–8 2.5 mm²
4 right indicator –
5 right tail light –
6 brake lights –
7 left tail light –
8 reversing light –
9 permanent supply (+) 2.5 mm²
10 charging supply (+) 2.5 mm²
11 earth for pin 10 –
12 trailer detection –
13 earth for pin 9 –

Humbaur's rules: do not join pins 11 and 13, and never bridge pin 10 to pin 9. Pin 10 should be live only with the engine running (via a relay). Charging through the socket is usually only a trickle charge.

Charging troubleshooting

Symptom Cause Fix
Booster will not start no D+/L signal, Euro 6 check the signal and detection settings
MPPT not charging in the morning PV voltage < battery + 5 V normal in low light
MPPT fault after installation panels connected before the battery order: battery → 10 s → panels
Caravan not charging while towing pin 10 without relay / thin cable relay in the car, 2.5 mm² cable
LiFePO4 not charging in winter temperature < +5 °C warm the battery

Charging checklist

Sources

Every figure on this page comes from the sources below (standards, manufacturer manuals, regulations). Before installing, check the current edition of the standard and the manual of your specific device.

  1. Victron Orion XS 12/12-50A – installation
  2. Votronic VCC 1212-30 – manual
  3. Victron SmartSolar MPPT 100/30 and 100/50 – manual
  4. Victron Lithium Battery Smart – operation
  5. Humbaur – pin assignment 7/13-pin (ISO 11446)
  6. EN 1648-2:2018 – standard preview

Questions & comments

If you spot an inaccuracy, please report it to info@carbonzorro.com.

The content of this Knowledge base is for general information and illustration only. It is not technical or legal advice and does not replace standards, regulations, manufacturers’ instructions or the work of a qualified installer. Carbon Zorro Sp. z o.o. makes every effort to keep the information accurate and up to date, but does not guarantee that it is complete and accepts no liability for any consequences of its use.

Knowledge base Carbon Zorro – Carbon Zorro Sp. z o.o., ul. Humańska 8, 02-789 Warszawa · carbonzorro.com
Content compiled from manufacturer catalogues; sources are given in each brand section. Specifications are subject to change.