Hot water in a motorhome: boiler, Combi, FrostControl and winterising
⚠️ Note: the water system connects to a gas boiler and to 12/230 V. Leave work on the gas boiler and on 230 V to a specialist. Use only parts approved for drinking water.
Hot water in motorhomes and caravans usually comes from a boiler (gas, electric or gas/electric) or a Combi unit (blown-air heating plus boiler, e.g. Truma Combi). Vehicles with wet central heating (e.g. Alde) take hot water from the boiler’s heat exchanger. All of these share one weakness: water freezes inside and splits the vessel, so manufacturers require a safety/drain valve and careful draining before frost.
Types of water heaters – comparison
| Appliance | Capacity | Energy | Data from manufacturer documentation |
|---|---|---|---|
| Truma Combi 4 (gas) | 10 l | 30 mbar gas + 12 V (fan, electronics) | gas 160–335 g/h; 12 V average 1.2 A, max. 6.5 A; quiescent current 1 mA |
| Truma Combi 6 | 10 l | gas + 12 V (E versions also 230 V) | gas up to 460 g/h |
| Truma Boiler (gas/electric) | 10 l | gas, optionally 230 V | gas 120 g/h; 230 V element 850 W or 1300 W (by version) |
| 230 V electric water heater | e.g. 5–14 l | 230 V | power per rating plate – e.g. Truma TT2 5 l 300 W, 14 l boiler 850 W (shop listings) |
| Alde (wet heating) | heat exchanger in boiler | gas / 230 V | fluid: 50 % glycol; safety valve 3.5 bar; water pressure reducer max. 3 bar |
Combi 4 – installation requirements from the manual: wall flue ≥ 300 mm from an opening window; water connections for 10 mm hose or 12 mm John Guest; with FrostControl, max. pump pressure 2.8 bar and max. system pressure 4.5 bar.
🛒 Products in the carbonzorro.com shop
- Combi Heater and Boiler
- Combi (E) Heater and Boiler
- Grzejnik+bojler Truma Combi D 4 iNet X Panel 4000 W/30 mbar/10 L/12V (Polish product page)
- Boiler
- Bojler Elektryczny Truma 14 Litrów 230V 850W (Polish product page)
- Carbest CozyWater 8 water heater 12 V 200 W - 8 l, stainless steel tank, thermostat
- Dometic bojler i ogrzewanie powietrza TwinBoost 4000 W (Polish product page)
Safety and drain valve (FrostControl)
Truma FrostControl is a current-free safety and drain valve fitted on the cold inlet of the boiler/Combi:
- it opens automatically below about 3 °C (at the valve) and dumps the boiler contents outside,
- it can only be closed again above about 7 °C,
- it must be installed in a heated space close to the appliance,
- it also works as a pressure safety valve (system pressure max. 4.5 bar),
- versions for 10 mm hose and 12 mm John Guest exist; a heating element is available to speed up filling in winter.
On the hot line after the heater, fit an air-inlet valve at the highest point – without air coming in the boiler will not empty completely.
🛒 Products in the carbonzorro.com shop
- Truma FrostControl 10 mm for hoses - current-free safety and drain valve with frost protection
- Truma FrostControl JG 12 mm - current-free safety and drain valve with frost protection, John Guest
- Truma FrostControl heating element for Combi 4, Combi 6 and Combi D - faster filling of the water system in winter
- REICH plastic drain valve with 2 inlets for 10-12 mm hose, up to 3 bar - water draining in motorhome and caravan
- REICH UniQuick drain valve 12 mm with 1 inlet - draining the drinking water system before winter
- LILIE brass shut-off valve for drinking water - ø 12 mm hose on both sides
- LILIE 10 mm non return valve - with spring diaphragm, yellow
- Reich zawór zwrotny z króćcem standardowym 10/12 mm UniQuick - 7,5 cm (Polish product page)
- Check Valve TB 10 mm
Boiler plumbing – connection sequence
- Cold water from the pump → check valve (so hot water cannot flow back into the cold line) → FrostControl → boiler cold inlet.
- Hot outlet → air-inlet valve at the highest point → taps.
- Route the FrostControl drain pipe outside the vehicle, with a continuous fall, no traps, and an outlet that cannot freeze shut.
- Gas, flue and 230 V – per the manufacturer’s installation manual; the work should be carried out by a qualified installer (see Gas).
Winterising the water system – sequence
For its boilers and Combi units Truma states: switch the pump off, open the taps, open the drain valve and leave the valves open; do not blow the boiler out with compressed air and do not use antifreeze without a boiler bypass. German magazine promobil gives the same rules for the whole motorhome system.
In detail:
- Switch off the pump and the boiler/Combi (gas and 230 V).
- Open all taps in the middle position (hot + cold) and the shower.
- Open the FrostControl / boiler drain valve.
- Open the line drains and the fresh-tank drain.
- Disconnect the pump suction hose or open the strainer to get rid of residual water; drain the accumulator (Fiamma A20 – drain in winter).
- Empty the grey tank and the toilet cassette; leave the grey dump valve open.
- Leave everything open until spring.
Winter touring (with heating)
- The tank and lines must be in the heated zone, or insulated and heated.
- FrostControl stays closed while the interior is above about 7 °C; with the heating off in frost it opens by itself – this is normal.
- Underfloor grey tank: insulation and a tank heater (e.g. for the Aplast 75 l tank), or leave the valve open with a bucket under the outlet.
🛒 Products in the carbonzorro.com shop
Hot-water service calendar
| When | Task | Source / note |
|---|---|---|
| before every frost without heating | drain completely (list above) | Truma, promobil |
| once a year | check the accumulator pre-charge | Fiamma A20 |
| once a year | disinfect tank and lines, replace filter cartridges | per product maker |
| every season | check the flue and the FrostControl drain outlet | appliance manual |
| every 2 years (mandatory in DE) | inspection of the gas system including the boiler | G 607 – see country rules |
Troubleshooting
| Symptom | Cause | What to do |
|---|---|---|
| FrostControl opens and dumps water | valve temperature below about 3 °C | heat the interior above about 7 °C and close; consider the FrostControl heating element |
| FrostControl will not close | too cold (below about 7 °C) | raise the interior temperature |
| Boiler does not empty completely | no air inlet | open the taps / air-inlet valve |
| Hot water flows into the cold line | missing or faulty check valve | fit/replace the check valve |
| No hot water on gas | no gas, closed valve, crash sensor tripped | see gas troubleshooting |
| Safety valve drips while running | pressure too high (mains water without reducer) | fit a pressure reducer |
🛒 Products in the carbonzorro.com shop
Sources
Every figure on this page comes from the sources below (standards, manufacturer manuals, regulations). Before installing, check the current edition of the standard and the manual of your specific device.
- Truma Combi 4 – technical data
- Truma – dealer catalogue 2025
- Truma Combi 4 – installation instructions
- Truma FrostControl – installation & operating instructions
- Alde 3020 – installation instructions
- Truma – draining the boiler (FAQ)
- promobil – Wasseranlage entleeren / Grauwassertank
- Fiamma A20 – accumulator manual
- DVFG – G 607-Prüfung für Freizeitfahrzeuge
If you spot an inaccuracy, please report it to info@carbonzorro.com.
The content of this Knowledge base is for general information and illustration only. It is not technical or legal advice and does not replace standards, regulations, manufacturers’ instructions or the work of a qualified installer. Carbon Zorro Sp. z o.o. makes every effort to keep the information accurate and up to date, but does not guarantee that it is complete and accepts no liability for any consequences of its use.
Knowledge base
Questions & comments