The fresh-water system is the part of a habitation conversion that owners change most often: a new pump, an extra filter, a bigger tank, a city-water inlet. This chapter covers fresh water – from the filler through the tank and pump to the taps. Hot water and winterising are in Hot water, FrostControl and winterising; grey water and the toilet are in Grey water, waste and toilet.

How it works – the two basic layouts

Caravan (typical) Motorhome (typical)
Fresh-water tank portable outside container (e.g. 40 l) or built-in built-in, in the heated zone or insulated under the floor
Pump submersible, in the container pressure (diaphragm) pump after the tank, or submersible
Pump control tap microswitches or a pressure switch pressure switch in the pump (stops when pressure is reached)
Pump supply caravan 12 V, plug at the water-inlet socket 12 V from the distribution unit (own fused circuit)
Grey water outlet under the floor → portable tank (e.g. Roll Tank) underfloor tank with a dump valve
Motorhome water system – overview
Fig. 1. Motorhome water system – overview – click to enlarge
Caravan water system – overview
Fig. 2. Caravan water system – overview – click to enlarge

Fresh-water components

  1. Filler – lockable and marked “water”. The example fillers in the shop take a 40 mm hose (Fawo wlew wody na ścianę boczną z klapką magnetyczną - białe, wąż 40 mm) or a 35 mm hose (FAP Bravo lockable water filler with hinged door, white, ø 35 mm hose connection - motorhome and caravan) – match the hose to the tank spigot.
  2. Fresh-water tank – made of drinking-water-grade plastic, with an inspection opening for cleaning, a vent/overflow, a level probe and a drain at the lowest point.
  3. Strainer before the pump – keeps sand and swarf out of the pump valves. Shurflo specifies a 50-mesh strainer on the suction side.
  4. Pump – submersible (simple, cheap, no pressure switch) or a diaphragm pressure pump with a pressure switch.
  5. Accumulator (expansion vessel) – reduces pump cycling and pulsing at the tap.
  6. Check valve – after the pump or on the city-water inlet, so water cannot flow back into the tank.
  7. Distribution – reinforced hose or 10/12 mm push-fit pipe (John Guest, UniQuick, Speedfit).
  8. Boiler / Combi with a safety and drain valve (e.g. Truma FrostControl) – see the hot-water chapter.
  9. Taps and shower, possibly an outdoor shower.
  10. City-water inlet – with a pressure reducer (see below).

Fresh-water tanks

Location. Ideally inside the heated zone (under a seat, in a double floor). An underfloor tank needs insulation and heating in winter. On Ducato/Jumper/Boxer chassis, tanks shaped for the wheel arches and the underfloor space are common – the shop lists, for example, Aplast 112 l tanks for the rear left wheel arch and 28 l tanks for the VW T6/Transit Custom.

Weight. One litre of water weighs about 1 kg – a full 100 l tank adds roughly 100 kg. Allow for it in the gross vehicle weight and the axle loads (see the registration document and the vehicle plate).

Tank fittings:

Water pumps – comparison and selection

Feature Submersible pump Diaphragm pressure pump
Location inside the tank outside the tank, in the heated zone
Control tap microswitches / external pressure switch built-in pressure switch
Running dry usually harmful – check the manual Shurflo Trail King: may run dry (manufacturer)
Noise quiet (under water) audible – mount on damping feet with flexible sections
Typical data (from product listings) e.g. Comet VIP-PLUS 20 l/min, 1.1 bar; Reich Power Jet 25 l/min, 2.1 bar e.g. Shurflo Trail King 7: 7 l/min; Fiamma Aqua 8: 7 or 10 l/min
Pump Flow Cut-out pressure Current Fuse Cable Flexible section
Shurflo Trail King 7 7 l/min 1.4 bar ± 0.4 (cut-in 0.8 bar) – 10 A time-delay min. 2.5 mm²; 6–15 m: 4 mm² ≥ 0.3 m of 13 mm hose
Fiamma Aqua 8 (7 l) 7 l/min 1.5 bar 1.4–2.7 A 7.5 A + 15 A switch min. 1.5 mm² ≥ 0.5 m of 13 mm hose
Fiamma Aqua 8 (10 l) 10 l/min 1.5 bar 3.8–4.7 A 7.5 A + 15 A switch min. 1.5 mm² ≥ 0.5 m of 13 mm hose

Notes from the manuals: Fiamma allows water at +4 to +40 °C and puts the A20 accumulator within the first metre after the pump. Shurflo recommends a switch rated ≥ 15 A in the (+) lead, main lines of ≥ 13 mm, and no PTFE tape on the port fittings.

Pressure pump circuit – plumbing and wiring
Fig. 3. Pressure pump circuit – plumbing and wiring – click to enlarge

Installing a pressure pump step by step

  1. Isolate the power – Fiamma advises disconnecting the battery (−) terminal while you work.
  2. Choose a location in the heated zone, close to and slightly below the tank, with service access. Fiamma: if mounted vertically, the motor goes above the pump head.
  3. Mount on damping feet (e.g. Silent Plate feet for the Aqua 8) – on a hard panel the pump resonates.
  4. Suction side: tank → strainer → flexible section (Shurflo ≥ 0.3 m, Fiamma ≥ 0.5 m, Ø 13 mm) → pump.
  5. Delivery side: pump → flexible section → accumulator (Fiamma: within the first metre) → check valve (if there is a city-water inlet) → split into cold supply and boiler feed.
  6. Electrics: a dedicated circuit from the distribution unit (Fiamma recommends the fuse box rather than a direct battery connection), fuse and switch in the (+) lead, cable size from the table above. Red = +, black = −.
  7. Commissioning: fill the tank, open the taps (cold and hot), switch the pump on and bleed until the water runs without air. Close the taps – the pump must stop once pressure is reached and must not keep restarting.
  8. Check every joint for leaks after 24 hours of use.

Accumulator – setting the pre-charge

An accumulator contains a diaphragm and an air cushion. Fiamma A20: pre-charge 0.9 bar for 1.5 bar pumps, max. 3 bar, check once a year; drain it for the winter. Set the pre-charge with the system depressurised, through the tyre-type valve. Too high a pre-charge and the vessel never takes in water; too low and the diaphragm is working all the time.

Pipes, hoses and fittings

12 mm push-fit systems (John Guest Speedfit, UniQuick, Carbest) – quick and serviceable. John Guest rules: cut the pipe square, deburr, fit a pipe insert, push in to the stop and pull-test. Fix pipe clips ≥ 60 mm from a fitting, every 300 mm horizontally and every 500 mm vertically (12 mm pipe). The Truma Combi 4 takes 10 mm hose or 12 mm John Guest connections.

Reinforced 10/12 mm hose with clamps – cheaper, but every clamp is a potential leak; use drinking-water hose and stainless clamps.

Topic Rule Source
Cutting push-fit pipe square, deburred, with insert John Guest
Fixing 12 mm pipe ≥ 60 mm from fitting; every 300 mm horizontal / 500 mm vertical John Guest
Shurflo pump ports no PTFE tape Shurflo
Main line diameter ≥ 13 mm (Shurflo) Shurflo
Combi 4 connections 10 mm hose or 12 mm John Guest Truma

City-water (mains) inlet

A mains inlet bypasses the pump. Mains pressure can exceed what a habitation system is rated for, so a pressure reducer is mandatory: Truma allows up to 2.8 bar pump pressure and 4.5 bar system pressure with FrostControl and requires a reducer on mains supply; Alde requires a reducer of max. 3 bar. Ready-made example: Reich Colorado city water connection with 0.7 bar pressure regulator and non-return valve, white - motorhome and caravan (0.7 bar reducer and check valve). A check valve after the inlet stops mains water from flowing back through the pump into the tank.

Drinking-water hygiene

Troubleshooting

Symptom Likely cause What to do
Pump restarts every few seconds with all taps closed leak on the delivery side, leaking check valve, faulty pressure switch check joints and taps; close section valves and watch
Pump cycles at low flow no accumulator, or wrong pre-charge fit/set an accumulator (A20: 0.9 bar)
Pump runs but no water empty tank, blocked strainer, air on suction side, split diaphragm check level, clean strainer, bleed with a tap open
Weak flow blocked aerators/strainer, hose too small, voltage drop clean; measure voltage at the pump while running
Pump does not start fuse, switch, pressure switch, plug at the inlet socket (caravan) measure voltage at the pump terminals
Musty/rotten smell biofilm in tank and lines disinfect, replace filters, clean tank via the inspection opening
Noisy pump no damping feet, rigid pipe at the pump flexible sections, rubber mounts

Installation checklist

Sources

Every figure on this page comes from the sources below (standards, manufacturer manuals, regulations). Before installing, check the current edition of the standard and the manual of your specific device.

  1. Shurflo Trail King 7 – product sheet
  2. Shurflo Trail King – installation instructions
  3. Fiamma Aqua 8 – manual
  4. Fiamma Aqua 8 – manual (electrical connection)
  5. Fiamma A20 – accumulator manual
  6. Truma FrostControl – installation & operating instructions
  7. Alde 3020 – installation instructions
  8. John Guest Speedfit – installation guide and specs
  9. Truma Combi 4 – installation instructions
  10. promobil – Wasseranlage entleeren / Grauwassertank

Questions & comments

If you spot an inaccuracy, please report it to info@carbonzorro.com.

The content of this Knowledge base is for general information and illustration only. It is not technical or legal advice and does not replace standards, regulations, manufacturers’ instructions or the work of a qualified installer. Carbon Zorro Sp. z o.o. makes every effort to keep the information accurate and up to date, but does not guarantee that it is complete and accepts no liability for any consequences of its use.