Rooflights – introduction (pp. 240–242)
Preliminary checks (p. 240)
General information - Before assembly, check that the roof thickness is compatible with the product and that the installation area is clean (use specific products, avoid alcohol-based products) - Before choosing the position, check that the product does not interfere with adjacent accessories (luggage racks, cables, roof reinforcements, cabinets inside) and that the inner and outer roof surfaces are flat
Use and maintenance (p. 240)
General information - Only use sealants suitable for the materials concerned - If not included, use round-head cylindrical screws to avoid damaging the screw seats - Periodically check that all rooflight screws are tight, especially after the first km after installation and before and after long journeys; if the opening device becomes stiff, lubricate it with a few drops of grease. Do not walk on the cover - Before driving, check the rooflight is closed and the cover intact. Do not open it while driving, in strong wind or rain; remove snow and ice. Always respect speed limits and the Highway Code - Clean only with neutral, non-aggressive detergents; for the Crystal cover use an acrylic-glass cleaner and a soft cloth. Never use glass cleaners, all-purpose cleaners, abrasives, dish-washing detergents, alcohol, solvents or corrosive liquids. The mosquito net can be washed with water and neutral detergent - Not suitable for vehicles or trailers intended for animal transport
Installation – milling radius (p. 241)
The drawings on p. 241 give, for each rooflight model, the maximum permissible milling radius for the square installation hole (tolerance 0/+1): Vent 50, Vent F Pro, Vent / Turbo-Vent / Turbo-Vent Premium, Vent 28F (radii R2…R8 as drawn; see the catalogue drawing).
Models and features (p. 242)
| Turbo-Vent | Turbo-Vent Premium | Turbo-Kit | Kit Turbo-Vent F | Kit Turbo-Vent 28 F | Vent F | Vent | Vent 28F | Vent 50 | Vent 40F | |
|---|---|---|---|---|---|---|---|---|---|---|
| Group | rooflight with fan | rooflight with fan | fan | fan | fan | without fan | without fan | without fan | without fan | without fan |
| Dimensions | 40 × 40 cm | 40 × 40 cm | – | – | – | 40 × 40 cm | 40 × 40 cm | 28 × 28 cm | 50 × 50 cm | 40 × 40 cm |
| Feeding tension | 12 V DC | 12 V DC | 12 V DC | 12 V DC | 12 V DC | – | – | – | – | – |
| Absorbed power | 36 W | 36 W | 4 W | 36 W | 25 W | – | – | – | – | – |
| Min. electric input | 0,3 A / 0,2 A | 0,3 A / 0,2 A | 0,2 A | 0,3 A | – | – | – | – | – | – |
| Max. electric input | 3 A | 3 A | 0,33 A | 3 A | 1,9 A | – | – | – | – | – |
| Max. air flow | 35 m³/min | 35 m³/min | 7,2 m³/min | 35 m³/min | 9 m³/min | – | – | – | – | – |
| Fan diameter | 300 mm | 300 mm | 240 mm | 300 mm | 180 mm | – | – | – | – | – |
| Permanent air flow | 80 cm² | 80 cm² | – | – | 50 cm² | 100 cm² | 80 cm² | 80 cm² | 150 cm² | 100 cm² |
| Certificates | CE, UKCA, RCM; E11 43R-01 0719; E24 10R-06 0530 | CE, UKCA, RCM; E11 43R-01 0719; E24 10R-06 0530 | – | CE, UKCA, RCM; E24 10R-06 0530 | CE, UKCA, RCM; E24 10R-05 0518 | E11 43R-01 0719 | E11 43R-01 0719 | E11 43R-01 0719 | E11 43R-01 0719 | E11 43R-01 0719 |
| Weight | 4,6 kg | 4,6 kg | 1,3 kg | 2 kg | 0,5 kg | 4,7 kg | 2,8 kg | 1,8 kg | 4,6 kg | 3,0 kg |
| Thermostat | standard | standard | – | standard | – | – | – | – | – | – |
| Fan speed | variable | variable | 2 | variable | 1 | – | – | – | – | – |
| Rollo-Vent | optional | optional | – | – | – | – | optional | – | – | – |
| Spoiler Universal | optional | optional | – | – | – | optional | optional | optional | optional | optional |
| Thermo-Vent 40 | optional | optional | – | – | – | – | optional | – | – | – |
Read from the rotated chart on p. 242; the catalogue prints "Variabile" (Italian: variable) for fan speed. RCM = the Australian regulatory compliance mark shown as a symbol.