Tech Wiki

Water pumps (pp. 269–272)

Preliminary checks and warnings (p. 269)

General information - Mount the pump on a solid surface, in a position convenient for filter cleaning and routine maintenance - The pump can be installed in any position; if vertical, put the motor above the hydraulic part - Mount the pump near the water tank for best performance - Use only cable terminals suited to the power cable diameter; wrong terminals cause voltage drop and heating at the terminal - Sanitise before first use to remove processing residues; check and clean the inlet filter periodically (at the start and end of the season) or when flow is low - In winter storage with temperatures < 0 °C, drain the whole system, especially the pump: disconnect the suction hose and run it for a few minutes until no water comes out of any tap - Sanitise pump and plumbing at least once a year or after long non-use; periodically check hydraulic connections loosened by vibration - Water supplied to Fiamma pumps must be at room temperature, not preheated by other equipment - Fiamma pumps can deliver water over a far greater distance and height than any current camper or motorhome requires

Aqua 8F (p. 270–271)

Aqua 8F – technical drawing (Fiamma catalogue, p. 270)
cat. p. 270
Aqua 8F – technical drawing (Fiamma catalogue, p. 270)
cat. p. 270
Aqua 8F – technical drawing (Fiamma catalogue, p. 270)
cat. p. 270
Aqua 8F – technical drawing (Fiamma catalogue, p. 270)
cat. p. 270
Aqua 8F – technical drawing (Fiamma catalogue, p. 271)
cat. p. 271
Aqua 8F – technical drawing (Fiamma catalogue, p. 271)
cat. p. 271
Aqua 8F – technical drawing (Fiamma catalogue, p. 271)
cat. p. 271
Aqua 8F – technical drawing (Fiamma catalogue, p. 271)
cat. p. 271
Aqua 8F – technical drawing (Fiamma catalogue, p. 271)
cat. p. 271
Aqua 8F – technical drawing (Fiamma catalogue, p. 271)
cat. p. 271

General information - Self-priming diaphragm pump - Materials: body PP, valves EPDM, membrane TPE, filter stainless steel - Dimensions: 7–10 l models 220 × 106 mm (205 / 62.5 mm); 13 l model 220 × 106 mm (235 / 62 mm) – see drawing

Technical features - Adjustable pressure switch (except the 13 l model) - 12 V supply and 4 chambers for high water flow - Compact; filter can be installed in the most convenient position - Made with KTW-compliant materials - Standard removable stainless-steel filter for easy cleaning - Plug with 1/2” thread - 7 and 10 l models: for standard circuits not needing high flow – low consumption, economical, fittings optional; 13 l: for circuits needing high flow - Mounting scheme: water tank → filter → pump (max. 1 m from tank) → A20 accumulator; switch, fuse and battery (+ red, – black); Ø 13 mm hoses; drain valve - Homologations: DM 174/2004, DIN EN 16421, EU 10/2011, DM 21/03/1973

Description Weight Item No. EAN
Aqua 8F (7 litres) 1,3 kg 07073B02- 🛒 Shop 8004815468255
Aqua 8F (10 litres) 1,3 kg 07073A02- 🛒 Shop 8004815450496
Aqua 8F (13 litres) * 2,2 kg 07073-02- 🛒 Shop 8004815450489
Technical features Aqua 8F (7 l) Aqua 8F (10 l) Aqua 8F (13 l)
Power supply 12 V 12 V 12 V
Absorption 1,4 A 3,1 A 2,4 A
Max. flow at 0 bar 7 l/min 10 l/min 13 l/min
Noise level 50 dB 52 dB 50 dB
Pressure switch cut-off 1,5 bar 2,1 bar 2,2 bar
Suction head 5 m 5 m 5 m
Nominal power 16,8 W 37,2 W 28,8 W
Problem Solution
The pump does not stop Check the supply (at least 12 V); check for leaks in the water circuit
The pump is noisy Check for vibrating pipes; an unstable surface increases noise and vibration; make sure the mounting feet are not over-compressed
The pump runs unevenly Check filter and pipes for obstructions; check the in/out valves for debris and loss of elasticity
The pump does not start Check the electrical connections; check for frozen water in the pump
The pump leaks Check for loose screws in the pressure-switch head or internal membrane; check the membrane for tears

* Angled and straight connectors for 13 mm hoses included. Flow/current-vs-pressure curves (0–2.2 bar) for each model are on p. 271.

A20 (p. 272)

A20 – technical drawing (Fiamma catalogue, p. 272)
cat. p. 272
A20 – technical drawing (Fiamma catalogue, p. 272)
cat. p. 272
A20 – technical drawing (Fiamma catalogue, p. 272)
cat. p. 272
A20 – technical drawing (Fiamma catalogue, p. 272)
cat. p. 272
A20 – technical drawing (Fiamma catalogue, p. 272)
cat. p. 272
A20 – technical drawing (Fiamma catalogue, p. 272)
cat. p. 272

General information - Universal expansion tank (membrane pressure accumulator) - Materials: body PA, membrane EPDM; 110 × 100 mm

Technical features - Eliminates the pulsating effect of the pump and supplies a constant flow; extends the life of pump and boiler - Pre-charged at 0.9 bar (13 psi) to suit Fiamma pumps; can be charged via its valve with a normal compressor to suit any pump, max. 8 bar (116 psi) - Horizontal or vertical installation; the internal diaphragm absorbs pressure knocks and stabilises pump operation - Plug with 1/2” thread - Made with KTW-compliant materials - With a non-Fiamma pump whose pressure switch is set higher, increase the pre-charge pressure - Homologations: DM 174/2004, DIN EN 16421, EU 10/2011, DM 21/03/1973

Description Weight Item No. EAN
A20 0,3 kg 02478-03- 🛒 Shop 8004815492137
Description Item No. EAN
Kit Connection for Aqua 8F / A20 (optional) 98657-013 🛒 Shop 8004815323745
Carbon Zorro Technical Wiki – Carbon Zorro Sp. z o.o., ul. Humańska 8, 02-789 Warszawa · carbonzorro.com